Handling Resized LUNs on RHEL 5

Perhaps it's a reflection of it being nearly two years since touching a non-Linux *NIX operating system, but I feel like I recall Solaris, Irix, HP/UX and AIX all handling resized LUNs far more gracefully than Linux currently seems to. I seem to recall that, if you resized a LUN on your storage array and presented it to your *N*X host, it was fairly non-disruptive to make that storage available to the filesystems residing on top of the LUN. Maybe I'm mis-remembering, but I can't help but feel that Linux is still showing it's lack of Enterprise-level maturity in this area.

Don't get me wrong, you can get Linux to make use of re-sized LUNs without having to reboot the box. So, that's definitely a good start. But, thus far, I haven't managed to tangle loose a method that doesn't require me to unmount a filesystem (and, if I'm using LVM or multipathd, having to disrupt them, as well).

That said, if you've ended up on this page, it's probably because you're trying to figure out "how do I get RedHat to make use of the extra space on the LUN my SAN administrator grew for me" and Google (et. al.) sent you here.

In sorting this issue out, it seems like the critically-deficient piece of the puzzle is the way in which Linux updates device geometry. As near as I can tell, it doesn't really notice geometry changes by itself, and, the tools available for making it see geometry changes aren't yet optimized for fully on-the-fly configuration changes. But, at least they do provide a method that saves you the several minutes that a physical host reboot can cost you.

In digging about an playing with my test system, what I've come up with is a workflow something like the following:

  1. Unmount any filesystems residing on the re-configured LUN (`umount`)
  2. Stop any logical volumes that are currently active on the LUN (`vgchange`)
  3. Nuke out any partitions that reference the last block of the LUN's previous geometry (`fdisk` for this)
  4. Tell linux to reread the geometry info for the LUN (`blockdev --rereadpt` for this)
  5. Re-create the previously-nuked partition, referencing the new ending-block  (typically `fdisk` - particularly if you have to do block offsets for your SAN solution - for this and add `kpartx` if you're using a multipathing solution)
  6. Grow any logical volume elements containing that re-created/grown partition (`pvresize` for this)
  7. Grow and restart any logical volumes containing that re-created/grown partition (`vgchange` and `lvresize` for this)
  8. Grow and remount any filesystems that were on the re-created/grown partition (`e2fsresize` for this - unless you're using an incompatible filesystem-type - and then `mount`)

Omitted from the list above, but should be inferred by the clueful reader is "stop and restart any processes that use the grown-LUN" (The `fuser` command is really helpful for this).

Obviously, if you're using something other than LVM for your logical volume managment (e.g., VxVM), the `vgchange`, `pvresize` and `lvresize` commands have to be replaced with the appropriate logical volume management system's equivalent commands.

At any rate, if anyone knows how I can call `blockdev --rereadpt` without needing to stop filesystems (etc.), please comment. I'm really trying to figure out the least disruptive way of accomodating resized LUNs and haven't quite got to where I think I should be able to get.

Friday, November 26, 2010

Linux Storage Multipathing in a Mixed-Vendor (NetApp/EMC) Environment

So, recently, I've been tasked with coming up with documentation for the junior staff that has to work with RedHat Enterprise Linux 5.x servers in a multi-vendor storage environment. I our particular environment, the two most likely candidates to be seen on a Linux server are NetApp and/or CLARiiON storage arrays.

Previously, I've covered how to set up an RHEL 5.x system to use the Linux multipath service with NetApp Filer-based fibrechannel storage. Below, I'll expand on that, a bit, by explaining how to deal with a multi-vendor storage environment where separate storage subsystems will use separate storage multipathing solutions. In this particular case, the NetApp Filer-based fibrechannel storage will continue to be managed with the native Linux storage multipathing solution (multipathd) and the EMC CLARiiON-based storage will use the EMC-provided storage multipathing solution, PowerPath. I'm not saying such a configuration will be normal in your environment or mine, it's just an "edge-case scenario" I explored in my testing environment just in case someone asked for it. It's almost a given that if you haven't tested or documented the edge-cases, someone will invariably want to know how to do it (and, conversely, if you test and document it, no one ever bothers you about how to do it in real life).

Prior to presentation of EMC CLARiiON-based storage to your mixed-storage system, you will want to ensure that:
  • CLARiiON-based LUNs are excluded from your multipathd setup
  • PowerPath software has been installed
To explicitly exclude CLARiiON-based storage from multipathd's management, it will be necessary to modify your system's /etc/multipath.conf file. You will need to modify this file's blacklist stanza to resemble the following:

blacklist {
        wwid DevId
        devnode "^(ram|raw|loop|fd|md|dm-|sr|scd|st)[0-9]*"
        devnode "^hd[a-z]"
        devnode "^cciss!c[0-9]d[0-9]*[p[0-9]*]"

          #############################################################################
        # Comment out the next four lines if management of CLARiiON LUNs is *WANTED*
        #############################################################################
        device {
                vendor "DGC"
                product "*"
        }

  }

The lines we're most interested in are the four that begin with the device { directive. These lines are what the blacklist interpreter uses to tell itself "ignore any devices whose SCSI inquiry returns a Vendor ID of "DGC".

I should note that I'd driven myself slightly nuts working out the above. I'd tried simply placing the 'device' entry directly in the 'blacklist' block. However, I found that, if I didn't contextualize it into a 'device' sub-block, the multipathd service would pretty much just flip me the bird and ignore the directive (without spitting out errors to tell me that it was doing so or why). Thus, it would continue to grab my CLARiiON LUNs until I nested my directives properly. The 'product' definition is, also, probably overkill, but, it works.

Once these are in place, restart the multipath daemon to get it to reread its configuration files. Afterwards, request storage and do the usual PowerPath tasks to bring the CLARiiON devices under PowerPath's control. Properly set up, this will result in a configuration similar to the following:
# multipath -l
360a98000486e2f34576f2f51715a714d dm-7 NETAPP,LUN
[size=25G][features=0][hwhandler=0][rw]
\_ round-robin 0 [prio=0][active]
 \_ 0:0:0:1 sda 8:0   [active][undef]
 \_ 0:0:1:1 sdb 8:16  [active][undef]
 \_ 1:0:0:1 sde 8:64  [active][undef]
 \_ 1:0:1:1 sdf 8:80  [active][undef]

# powermt display dev=all
Pseudo name=emcpowera
CLARiiON ID=APM00034000388 [stclnt0001u]
Logical device ID=600601F8440E0000DBE5E2FEF1E1DF11 [LUN 13]
state=alive; policy=BasicFailover; priority=0; queued-IOs=0;
Owner: default=SP A, current=SP B       Array failover mode: 1
==============================================================================
--------------- Host ---------------   - Stor -   -- I/O Path --  -- Stats ---
###  HW Path               I/O Paths    Interf.   Mode    State   Q-IOs Errors
==============================================================================
   0 qla2xxx                  sdc       SP A1     unlic   alive       0      0
   0 qla2xxx                  sdd       SP B1     unlic   alive       0      0
   1 qla2xxx                  sdg       SP A0     active  alive       0      0
   1 qla2xxx                  sdh       SP B0     active  alive       0      0

As can be seen from the above, the NetApp LUN(s) are showing up under the multipathd's control and the CLARiiON LUNs are showing up under PowerPath's control. Neither multi-pathing solution is seeing the others' devices.

You'll also note that the Array failover mode is set to "1". In my test environment, the only CLARiiON I have access to is in dire need of a firmware upgrade. Its firmware doesn't support mode "4" (ALUA). Since I'm using this test configuration to test both PowerPath and native multipathing, I had to set the LUN to a mode that both the array and multipathd supported to get my logs to stop getting polluted with "invalid mode" settings. Oh well, hopefully a hardware refresh is coming to my lab.

Lastly, you'll also likely note that I'm running PowerPath in unlicensed mode. Again, this is a lab scenario where I'm tearing stuff down and rebuilding, frequently. Were it a production system, the licensing would be in place to enable all of the PowerPath functionality.

Wednesday, November 17, 2010

Linux Multipath Path-Failure Simulation

Previously, I've discussed how to set up the RedHat Linux storage multipathing software to manage fibrechannel-based storage devices. I didn't, however, cover how one tests that such a configuration is working as intended.
When it comes to testing resilient configurations, one typically has a number of testing options. In a fibrechannel fabric situation, one can do any of:
  • Offline a LUN within the array
  • Down an array's storage processors and/or HBAs
  • Pull the fibrechannel connection between the array and the fibrechannel switching infrastructure
  • Shut off a switch (or switches) in a fabric
  • Pull connections between switches in a fabric
  • Pull the fibrechannel connection between the fibrechannel switching infrastructure and the storage-consuming host system
  • Disable paths/ports within a fibrechannel switch
  • Disable HBAs on the storage-consuming host systems
  • Disable particular storage targets within the storage-consuming host systems
Generally, I favor approaches that limit the impact of the tested scenario as much as possible. I favor approaches that limit the likelihood of introducing actual/lasting breakage into the tested configuration.
I also tend to favor approaches where I have as much control of the testing scenario as possible. I'm an impatient person and having to coordinate outages and administrative events with other infrastructure groups and various "stakeholders" can be a tiresome, protracted chore. Some would say that indicates I'm not a team-player: I like to think that I just prefer to get things done efficiently and as quickly as possible. Tomayto/tomahto.
Through most of my IT career, I've worked primarily the server side of the house (Solaris, AIX, Linux ...and even - *ech* - Windows) - whether as a systems administrator or as an integrator. So, my testing approaches tend to be oriented from the storage-consumer's view of the world. If I don't want to have to coordinate outside of a server's ownership/management team, I'm pretty much limited to the last three items on the above list: yanking cables from the server's HBAs, disabling the server's HBAs and disabling storage targets within the server.
Going back to the avoidance of "introducing actual/lasting breakage", I tend to like to avoid yanking cables. At the end of the day, you never know if the person doing the monkey-work of pulling the cable is going to do it like a surgeon or like a gorilla. I've, unfortunately, been burned by run-ins with more than a few gorillas. So, if I don't have to have cables physically disconnected, I avoid it.
Being able to logically disable an HBA is a nice test scenario. It effects the kind of path-failure scenario that you're hoping to test. Unfortunately, not all HBA manufacturers seem to include the ability to logically disable the HBA from within their management utilities. Within commercial UNIX variants - like Solaris or AIX - this hasn't often proven to be a problem. Under Linux, however, the abilty to logically disable HBAs from within their management utilities seems to be a bit "spotty".
Luckily, where the HBA manufacturers sometimes leave me in the lurch, RedHat Linux leaves me some alternatives. In the spirit of the Linux DIYism, those alternatives aren't really all that fun to deal with ...until you write tools, for yourself, that removes some of the pain. I wrote two tools to help myself in this area: one is a tool which offlines designated storage paths and one is a tool which attempts to restore those downed storage paths.
Linux makes it possible to change the system-perceived state of a given device path by writing the term "offline" to the file location, /sys/block/${DEV}/device/state. Thus, were one to want to make the OS think that the path to /dev/sdg was down, one would execute the command, `echo "offline" > /sys/block/sdg/device/state`. All that my path-downing script is makes it so you can down a given /dev/sdX device by executing `pathdown.sh <DEVICE>` (e.g., `pathdown sdg`). There's minimal logic built in to verify that the named /dev/sdX device is a real, downable device and it provides a post-action status of that device, but, other than that, it's a pretty simple script.
To decide which path one wants to down, it's expected that the tester will look at the multipather's view of its managed devices using `multipath -l <DEVICE>` (e.g., `multipath -l mpath0`). This command will produce output similar to the following:
mpath0 (360a9800043346d364a4a2f41592d5849) dm-7 NETAPP,LUN
[size=20G][features=0][hwhandler=0][rw]
\_ round-robin 0 [prio=0][active]
 \_ 0:0:0:1 sda 8:0   [active][undef]
 \_ 0:0:1:1 sdb 8:16  [active][undef]
 \_ 1:0:0:1 sdc 8:32  [active][undef]
 \_ 1:0:1:1 sdd 8:48  [active][undef]
Thus, if one wanted to deactivate one of the channels in the mpath0 multipathing group, one might issue the command  `pathdown sdb`. This would result in the path associated with /dev/sdb being taken offline. After taking this action, the output of `multipath -l mpath0` would change to:
mpath0 (360a9800043346d364a4a2f41592d5849) dm-7 NETAPP,LUN
[size=20G][features=0][hwhandler=0][rw]
\_ round-robin 0 [prio=0][active]
 \_ 0:0:0:1 sda 8:0   [active][undef]
 \_ 0:0:1:1 sdb 8:16  [failed][faulty]
 \_ 1:0:0:1 sdc 8:32  [active][undef]
 \_ 1:0:1:1 sdd 8:48  [active][undef]
Typically, when doing such testing activities, one would be performing a large file operation to the disk device (preferably a write operation). My test sequence is typically to
  1. Start an `iostat` job, grepping for the devices I'm interested in, and capturing the output to a file
  2. start up a file transfer (or even just a `dd` operation) into the device.
  3. Start downing paths as the transfer occurs
  4. Wait for the transfer to complete, then kill the `iostat` job
  5. Review the captured output from the `iostat` job to ensure that the I/O behaviors I expected to see actually occurred
In the testing environment I had available when I wrote this page, I was using a NetApp filer presenting blockmode storage via fibrechannel. The NetApp multipathing plugin supports concurrent, multi-channel operations to the target LUN. Thus, the output from my `iostat` job will show uniform I/Os across all paths to the LUN, and then show outputs drop to zero on each path that I offline. Were I using an array that only supported Active/Passive I/O operations, I would expect to see the traffic move from the downed path to one of the failover paths, instead.
So, great: you've tested that your multipathing system behaves as expected. However, once you've completed that testing, all of the paths that you've offlined have stayed offline. What to do about it?
The simplest method is to reboot the system. However, I abhor knocking my systems' `uptime` if I don't absolutely have to. Fortunately, much as Linux provides the means to offline paths, it provides the means for reviving them (well, to be more accurate, to tell it "hey, go check these paths and see if they're online again"). As with offlining paths, the methods for doing so aren't currently built into any OS-provided utilities. What you have to do is:
  1. Tell the OS to delete the device paths
  2. Tell the OS to rescan the HBAs for devices it doesn't currently know about
  3. Tell the multipath service to look for changes to paths associated with managed devices
The way you tell the OS to (gracefully) delete device paths is to write a value to a file. Specifically, one writes the value "`1" to the file /sys/block/${DEV}/device/delete. Thus, if one is trying to get the system to clean up for the downed device path, /dev/sdb, one would issue the command `echo "1" > /sys/block/sdb/device/delete`.
The way you tell the OS to rescan the HBAs is to issue the command `echo "- - -" >  /sys/class/scsi_host/${HBA}/scan`. In Linux, the HBAs are numbered in the order found and named "hostN" (i.e., "host0", "host1", etc.). Thus, to rescan HBA 0, one would issue the command `echo "- - -" >  /sys/class/scsi_host/host0/scan` (for good measure, rescan all the HBAs).
The way to tell the multipath service to look for changes to paths associated with managed devices is to issue the command `multipath` (I acutally use `multipath -v2` because I like the more verbose output that tells me what did or didn't happen as a result of the command). Granted, the multipath service periodically rescans the devices it manages to find state-change information, but I don't like to wait for systems to "get around to it".
All that my path fixing script does is rolls up the above, three steps into one, easy to remember and use command.
Depending on how you have logging configured on your system, the results of all the path offlining and restoration will be logged. Both the SCSI subsystem and the multipathing daemon should log events. Thus, you can verify the results of your activities by looking in your system logs.
That said, if the system you're testing is hooked up to an enterprise monitoring system, you will want to let your monitoring groups know that they need to ignore the red flags you'll be generating on their monitoring dashboards.