Showing posts with label CLARiiON. Show all posts
Showing posts with label CLARiiON. Show all posts

Friday, July 8, 2011

CLARiiON Report Data Verification

Earlier this year, the organization I work for decided to put into production an enterprise-oriented storage resource management (SRM) system. The tool we bought is actually pretty cool. We install collectors into each of our major data centers and they pull storage utilization data off of all of our storage arrays, SAN switches and storage clients (you know: the Windows and UNIX boxes that use up all that array-based storage). Then, all those collectors pump out the collected data to a reporting server at our main data center. The reporting server is capable of producing all kinds of nifty/pretty reports: configuration snapshots, performance reports, trending reports, utilization profiles, etc.

As cool as all this is, you have the essential problem of "how do I know that the data in all those pretty reports is actually accurate?" Ten or fifteen years ago, when array-based storage was fairly new and storage was still the realm of systems administrators with coding skills, you'd ask you nearest scruffy misanthrope, "could you verify the numbers on this report," and get an answer back within a few hours (and then within minutes each subsequent time you asked). Unfortunately, in the modern, GUI-driven world, asking your storage guys to verify numbers can be like pulling teeth. Many modern storage guys aren't really coders and frequently don't know the quick and easy way to get you hard numbers out of the devices they manage. In some cases, you may watch them cut and paste from the individual array's management web UIs into something like MicroSoft Calculator. So, you'll have to wait and, often times, you'll have to continually prod them for the data because it's such a pain in the ass for them to produce.

With our SRM rollout, I found myself in just such a situation. Fortunately, I've been doing Unix system adminstration for the best part of 20 years and, therefore, am rather familiar with scripting. I frequently wish I was able to code in better reporting languages, but I just don't have the time to keep my "real" coding skills up to par. I'm also not terribly patient. So, after waiting a couple weeks for our storage guys to get me the numbers I'd asked for, I said to myself, "screw it: there's gotta be a quicker/better way."

In the case of our CLARiiONs, that better way was to use the NaviCLI (or, these days, the NaviSECCLI). This is a tool set that has been around a looooooong time, in one form or another, and has been available for pretty much any OS that you might attach to a CLARiiON as a storage client. These days, it's a TCP/IP-based commandline tool - prior to NaviCLI, you either had platform-specific tools (IRIX circa 1997 had a CLI-based tool that did queries through the SCSI bus to the array) or you logged directly into the array's RS232 port and used its onboard tools (hopefully, you had a terminal or terminal program that allowed you to capture output) ...but I digress.

If you own EMC equipment, you've hopefully got maintenance contracts that give you rights to download tools and utilities from the EMC support site. NaviCLI is one such tool. Once you install it, you have a nifty little command-line tool that you can wrap inside of scripts. You can create these scripts to both provisioning tasks and reporting tasks. My use, in this case, was reporting.'

The SRM we bought came with a number of canned-reports - including ones for CLARiiON devices. Unfortunately, the numbers we were getting from our SRM were indicating that we only had about 77TiB on one of our arrays when the EMC order sheets said we should have had about 102TiB. That's a bit of a discrepancy. I was able to wrap some NaviCLI commands into a couple scripts (one that reported on RAID-group capacity and one that reported physical and logical disk capacities [ed.: please note that these scripts are meant to be illustrative of what you can do, but aren't really something you'd want to have as the nexus of your enterprise-reporting strategy. They're slow to run, particularly on larger arrays]) and verify that the 77TiB was sort of right and that the 102TiB was also sorta right. The group capacity script basically just spits out two numbers - total raw capacity and total capacity allocatable to clients (without reporting on how much of either is already allocated to clients). The disk capacity script reports how the disks are organized (e.g., RAID1, RAID5, Spare, etc.) - printing total number of disks in each configuration category and how much raw capacity that represented. Basically, the SRM tool was reporting the maximum number of blocks that were configured into RAID groups, not the total raw physical blocks in the array that we'd thought it was supposed to report.

Having these number in hand allowed us to tear apart the SRM's database queries and tables so that we could see what information it was grabbing, how it was storing/organizing it and how to improve on the vendor-supplied standard reports. Mostly, it consisted of changing the titles of some existing fields and adding some fields to the final report.

Yeah, all of this begs the question "what was the value of buying an SRM when you had to reverse-engineer it to make the presented data meaningful?" To be honest, "I dunno." I guess, at the very least, we bought a framework through which we could put together pretty reports and ones that were more specifically meaningful to us (though, to be honest, I'm a little surprised that we're the only customers of the SRM vendor to have found the canned-reports to be "sadly lacking"). It also gave me an opportunity to give our storage guys a better idea of the powerful tools they had available to them if only they were willing to dabble at the command line (even on Windows).

Still the vendor did provide a technical resource to help us get things sorted out faster than we might have done without that assistance. So, I guess that's something?

Friday, November 26, 2010

Linux Storage Multipathing in a Mixed-Vendor (NetApp/EMC) Environment

So, recently, I've been tasked with coming up with documentation for the junior staff that has to work with RedHat Enterprise Linux 5.x servers in a multi-vendor storage environment. I our particular environment, the two most likely candidates to be seen on a Linux server are NetApp and/or CLARiiON storage arrays.

Previously, I've covered how to set up an RHEL 5.x system to use the Linux multipath service with NetApp Filer-based fibrechannel storage. Below, I'll expand on that, a bit, by explaining how to deal with a multi-vendor storage environment where separate storage subsystems will use separate storage multipathing solutions. In this particular case, the NetApp Filer-based fibrechannel storage will continue to be managed with the native Linux storage multipathing solution (multipathd) and the EMC CLARiiON-based storage will use the EMC-provided storage multipathing solution, PowerPath. I'm not saying such a configuration will be normal in your environment or mine, it's just an "edge-case scenario" I explored in my testing environment just in case someone asked for it. It's almost a given that if you haven't tested or documented the edge-cases, someone will invariably want to know how to do it (and, conversely, if you test and document it, no one ever bothers you about how to do it in real life).

Prior to presentation of EMC CLARiiON-based storage to your mixed-storage system, you will want to ensure that:
  • CLARiiON-based LUNs are excluded from your multipathd setup
  • PowerPath software has been installed
To explicitly exclude CLARiiON-based storage from multipathd's management, it will be necessary to modify your system's /etc/multipath.conf file. You will need to modify this file's blacklist stanza to resemble the following:

blacklist {
        wwid DevId
        devnode "^(ram|raw|loop|fd|md|dm-|sr|scd|st)[0-9]*"
        devnode "^hd[a-z]"
        devnode "^cciss!c[0-9]d[0-9]*[p[0-9]*]"

          #############################################################################
        # Comment out the next four lines if management of CLARiiON LUNs is *WANTED*
        #############################################################################
        device {
                vendor "DGC"
                product "*"
        }

  }

The lines we're most interested in are the four that begin with the device { directive. These lines are what the blacklist interpreter uses to tell itself "ignore any devices whose SCSI inquiry returns a Vendor ID of "DGC".

I should note that I'd driven myself slightly nuts working out the above. I'd tried simply placing the 'device' entry directly in the 'blacklist' block. However, I found that, if I didn't contextualize it into a 'device' sub-block, the multipathd service would pretty much just flip me the bird and ignore the directive (without spitting out errors to tell me that it was doing so or why). Thus, it would continue to grab my CLARiiON LUNs until I nested my directives properly. The 'product' definition is, also, probably overkill, but, it works.

Once these are in place, restart the multipath daemon to get it to reread its configuration files. Afterwards, request storage and do the usual PowerPath tasks to bring the CLARiiON devices under PowerPath's control. Properly set up, this will result in a configuration similar to the following:
# multipath -l
360a98000486e2f34576f2f51715a714d dm-7 NETAPP,LUN
[size=25G][features=0][hwhandler=0][rw]
\_ round-robin 0 [prio=0][active]
 \_ 0:0:0:1 sda 8:0   [active][undef]
 \_ 0:0:1:1 sdb 8:16  [active][undef]
 \_ 1:0:0:1 sde 8:64  [active][undef]
 \_ 1:0:1:1 sdf 8:80  [active][undef]

# powermt display dev=all
Pseudo name=emcpowera
CLARiiON ID=APM00034000388 [stclnt0001u]
Logical device ID=600601F8440E0000DBE5E2FEF1E1DF11 [LUN 13]
state=alive; policy=BasicFailover; priority=0; queued-IOs=0;
Owner: default=SP A, current=SP B       Array failover mode: 1
==============================================================================
--------------- Host ---------------   - Stor -   -- I/O Path --  -- Stats ---
###  HW Path               I/O Paths    Interf.   Mode    State   Q-IOs Errors
==============================================================================
   0 qla2xxx                  sdc       SP A1     unlic   alive       0      0
   0 qla2xxx                  sdd       SP B1     unlic   alive       0      0
   1 qla2xxx                  sdg       SP A0     active  alive       0      0
   1 qla2xxx                  sdh       SP B0     active  alive       0      0

As can be seen from the above, the NetApp LUN(s) are showing up under the multipathd's control and the CLARiiON LUNs are showing up under PowerPath's control. Neither multi-pathing solution is seeing the others' devices.

You'll also note that the Array failover mode is set to "1". In my test environment, the only CLARiiON I have access to is in dire need of a firmware upgrade. Its firmware doesn't support mode "4" (ALUA). Since I'm using this test configuration to test both PowerPath and native multipathing, I had to set the LUN to a mode that both the array and multipathd supported to get my logs to stop getting polluted with "invalid mode" settings. Oh well, hopefully a hardware refresh is coming to my lab.

Lastly, you'll also likely note that I'm running PowerPath in unlicensed mode. Again, this is a lab scenario where I'm tearing stuff down and rebuilding, frequently. Were it a production system, the licensing would be in place to enable all of the PowerPath functionality.